The Unitron UFC-180T with 28V DC is a combo 180 kVA ground power unit and 28V DC (GPU) for servicing the largest commercial and military aircraft on the market today. This unit operates on 3 phase input voltage from your hangar or your local facility. The dual outputs provided can be single source controlled, be individually voltage regulated and line drop compensated, and configured for partial redundancy.

Specifications

  • IP55
  • Certified to UL 1012
  • 3 Phase, 380-480VAC Input (Other 3 Phase Input Voltages Available On Request)
  • Indoor/Outdoor (Hangar/Ramp) Use
  • <= 5% Input Current Distortion
  • Automatic Input Line Monitoring
  • Advanced Integrated Display (AID) Console
  • 8000 Event Log / Diagnostics
  • Internal Communication Ports - USB, RJ45 (ETHERNET), RS485 (Modbus), & RS232
  • External Communication Ports - RJ45 (ETHERNET) & USB
  • 15% Automatic Line Drop Compensation
  • Emergency Power "OFF" Switch
  • 18-Inch Hazard Area Clearance
  • I/O Voltage, Current, & Frequency Monitoring
  • Elapsed Time Meter
  • Sleep Mode
  • Front Panel Voltage Adjust
  • Front Panel Summary Fault Indicators
  • Input & Output Cable Racks
  • Input High Voltage Transient Protection
  • Multi Language (Romanization) Display - English, French, German, Italian, Portuguese, Russian and Spanish, Others - Request at time of quote

Input

  • Input Current Distortion: <= 5%, typically 3%
  • Input Voltage: 380 to 480 V, +10%, -15%, 3 or 4 wire plus ground
  • Frequency: 45 - 65 Hz +/- 10%
  • Phase Rotation: Any
  • Protection: Over/undervoltage, loss of phase, overcurrent, short circuit. Voltage transient protection IAW IEEE C62.41.1, Location Cat. B/C
  • Inrush Current: No greater than 100% of full load current

Environmental

  • Acoustical Noise: < 65 dBA maximum at 5 feet (1.5m)
  • Temperature Range: -40 degree C to +55 degree C
  • Relative Humidity: 10 - 95%, Non-Condensing
  • Ingress of Water: Type 3RX, IP55

Energy Factors

  • Efficiency: 94% typical at full load, 92% typical at half load; varies depending on configuration
  • Energy Efficiency Ratio: 20.0 typical

Output

  • Power Rating: 180 kVA
  • Power Factory Range: 0.5 lagging to 0.8 leading
  • Overload: 100% continuous, 110% for 60 min, 125% for 10 min, 150% for 2 min, 200% for 20 sec
  • Voltage: 115/200 volts, 3, 4 wire, grounded neutral
  • Crest Factor: 1.414 +/- 3%
  • Voltage Regulation: +/- 1.0% under all conditions of line, balanced loads and temperature
  • Voltage Transients: IAW MIL-STD-704F
  • Frequency Regulation: 400 Hz +/- 0.01% under all conditions of line, load and temperature
  • Frequency Transients: None
  • Phase Angle Regulation: +/- 1 degree for balanced loads; +/- 2 degree for unbalanced loads
  • Harmonic Distortion: 2.0% maximum
  • Protection: Overload, short circuit, over/undervoltage and safety disconnect
  • Automatic Line Drop Compensation (ALDC): 15%

DC Output - Option 1 - UDC-420

  • Full Rated Load: 425 amps continuous
  • Engine Start Capacity (10% duty cycle): Adjustable up to 1600 amps for 35 seconds, 2000 amps for 30 seconds
  • Overload (10% duty cycle): 600 amps for 1 hour 1000 amps for 1 minute
  • Voltage: 28 VDC, 2 wire, grounded negative
  • Voltage Regulation:
    • 100% continuous rated load and +/-10% input voltage: +/- 0.5%
    • No load to rated load with nominal input voltage: IAW ISO 6858 & MIL-STD-704F
    • Overload with nominal input voltage: See start mode curves
  • Voltage Adjust: 28 VDC +/- 10%
  • Current Limit Adjust: 150A to full rated current
  • Protection: Overload, short circuit, over voltage and safety disconnect
  • Automatic Line Drop Compensation (ALDC): 10%

DC Output - Option 2 - UDC-620

  • Full Rated Load: 600 amps continuous
  • Engine Start Capacity (10% duty cycle): Adjustable up to 1600 amps for 1 minute or 2000 amps for 30 seconds
  • Overload (10% duty cycle): 1000 amps for 10 minutes
  • Voltage: 28 VDC, 2 wire, grounded negative
  • Voltage Regulation:
    • 100% continuous rated load and +/-10% input voltage: +/- 0.5%
    • No load to rated load with nominal input voltage: IAW ISO 6858 & MIL-STD-704F
    • Overload with nominal input voltage: See start mode curves
  • Voltage Adjust: 28 VDC +/- 10%
  • Current Limit Adjust: 150A to full rated current
  • Protection: Overload, short circuit, over voltage and safety disconnect
  • Automatic Line Drop Compensation (ALDC): 10%

Dimensions and Weight

  • Enclosure: NEMA 3RX Corrosion Resistant
  • Cooling: Forced Convection

Standards

  • EN 61000-6-2*: Electromagnetic compatibility, Immunity standard for industrial environments
  • EN 61000-6-4*: Electromagnetic compatibility, Emission standard for industrial environments
  • 2006/95/EC*:Low Voltage Directive
  • ISO 1540: Characteristics of aircraft electrical system
  • ISO 6858: Aircraft ground support electrical supplies
  • SAE ARP 5015: Ground equipment 400Hz ground power performance requirement
  • MIL-STD-704F: Aircraft electric power characteristics
  • MIL-STD-1472: Human Engineering Design Criteria
  • DFS-400: Specification for 400Hz aircraft power supply
*Defined Basis of CE Mark Certification

Available Options

**If any options below are required, please request at time of quote.
  • Custom Paint & Decals (Standard Color - White)
  • CE Mark Certified
  • Alternate input voltage range 3 Phase
  • Various Convenience Outlets (Specify Voltage and Frequency)
  • 50 or 100 Foot Input Power Cable (Pigtail, Specify Required Length)
  • AC Output Power Cable with Plug (available in 30 or 60 foot standard lengths), specify required length
  • Output Universal Aircraft Safety Interlock Circuit Disconnect (Single or Dual)
  • Output Safety Disconnect
  • Second 28VDC output
  • 300% overload for 6 seconds
  • Alternate third or fourth outputs - 28VDC each at 600 Amps continuous with Individual Safety Disconnect from aircraft
  • Alternately Selectable 400Hz or 270VDC at same kW ratings, either output
  • TCP/IP/Ethernet interface (Modbus)
  • No Break Power Transfer Compatible
  • Indoor Touch Screen Panel Individual Output Voltage Regulation / ALDC
  • Alternate Mounting Configurations Available
  • CSA Certified
  • Ground Fault Monitor
  • Neutral Interrupt Protection
  • Universal Safety Interlock
Alternate Models
UFC-180T-420UDC425 amps continuous / 2000 amps max
UFC-180T-620UDC600 amps continuous / 2000 amps max