The Unitron 45 kVA with 28V DC PwrKart series is a lightweight AC / DC mobile GPU for aircraft ground power applications in the hangar or ramp area. The dual output AC/DC PwrKart provides simultaneous AC and DC power from a single unit.

Features

  • IP55
  • Certified to UL 1012
  • Indoor/Outdoor (Hangar/Ramp) Use
  • Automatic Input Line Monitoring
  • Advanced Integrated Display (AID) Console
  • 8000 Event Log / Diagnostics
  • TCP/IP/Ethernet interface (Modbus)
  • Internal Communication Ports - USB, RJ45 (ETHERNET), RS485 (Modbus), & RS232
  • External Communication Ports - RJ45 (ETHERNET) & USB
  • Emergency Power "OFF" Switch
  • 18-Inch Hazard Area Clearance
  • Voltage, Current, & Frequency Monitoring
  • Front Panel Voltage Adjust
  • Elapsed Time Meter
  • Sleep Mode
  • Front Panel Summary Fault Indicators
  • Output Current Limit Adjust from 150A to full rated current
  • Input & Output Cable Racks
  • Input High Voltage Transient Protection
  • Multi Language (Romanization) Display -English, French, German, Italian, Portuguese, Russian and Spanish, Others - Specify

AC Input

  • Voltage: 380 - 480V, +/- 10%, 3O, 3 or 4 wire plus ground (Additional alternative voltages available from 208V - 240V 3 PH)
  • Frequency: 50 - 60 Hz +/- 10%
  • Phase Rotation: Any
  • Protection: Over/undervoltage, loss of phase, overcurrent, short circuit. Voltage transient protection IAW IEEE C62.41.1, Location Cat. B/C
  • Inrush Current: No greater than 100% of full load current

DC Output - Option 1 - UDC-420

  • Full Rated Load: 425 amps continuous
  • Engine Start Capacity (10% duty cycle): Adjustable up to 1600 amps for 35 seconds, 2000 amps for 30 seconds
  • Overload (10% duty cycle): 600 amps for 1 hour 1000 amps for 1 minute
  • Voltage: 28 VDC, 2 wire, grounded negative
  • Voltage Regulation:
    • 100% continuous rated load and +/-10% input voltage: +/- 0.5%
    • No load to rated load with nominal input voltage: IAW ISO 6858 & MIL-STD-704F
    • Overload with nominal input voltage: See start mode curves
  • Voltage Adjust: 28 VDC +/- 10%
  • Current Limit Adjust: 150A to full rated current
  • Protection: Overload, short circuit, over voltage and safety disconnect
  • Automatic Line Drop Compensation (ALDC): 10%

DC Output - Option 2 - UDC-620

  • Full Rated Load: 600 amps continuous
  • Engine Start Capacity (10% duty cycle): Adjustable up to 1600 amps for 1 minute or 2000 amps for 30 seconds
  • Overload (10% duty cycle): 1000 amps for 10 minutes
  • Voltage: 28 VDC, 2 wire, grounded negative
  • Voltage Regulation:
    • 100% continuous rated load and +/-10% input voltage: +/- 0.5%
    • No load to rated load with nominal input voltage: IAW ISO 6858 & MIL-STD-704F
    • Overload with nominal input voltage: See start mode curves
  • Voltage Adjust: 28 VDC +/- 10%
  • Current Limit Adjust: 150A to full rated current
  • Protection: Overload, short circuit, over voltage and safety disconnect
  • Automatic Line Drop Compensation (ALDC): 10%

AC Output

  • Power Rating: 45 kVA
  • Power Factor Range: 0.5 lagging to 0.8 leading
  • Overload: 100% continuous, 110% for 60 min, 125% for 10 min, 150% for 2 min, 200% for 20 sec (45kVA)
  • Crest Factor: 1.414 +/- 3%
  • Voltage: 115/200 volts, 3O, 4 wire, grounded neutral
  • Voltage Adjust +/- 15% on 380-480V, 208 VAC, adjustable +/-10%
  • Voltage Regulation: +/- 1.0% under all conditions of line, balanced loads and temperature
  • Voltage Transients: IAW MIL-STD-704F
  • Frequency Regulation: 400 Hz +/- 0.01% under all conditions of line, load and temperature
  • Frequency Transients: None
  • Phase Angle Regulation: +/- 1 degree for balanced loads; +/- 2 degree for unbalanced loads
  • Harmonic Distortion: 2.0% maximum
  • Protection: Overload, short circuit, over/under voltage and safety disconnect
  • Automatic Line Drop Compensation (ALDC): 15%

Environmental

  • Acoustical Noise: < 65 dBA maximum at 5 feet (1.5m)
  • Temperature Range: -40 degree C to +55 degree C
  • Relative Humidity: 10 - 95%, Non-Condensing
  • Ingress of Water: Type 3RX, IP55

Mechanical Specifications

  • Size: See images on listing.
  • Weight: 45.0kVA = 827 lbs (375 kg)
  • Enclosure: NEMA 3RX Corrosion Resistant
  • Cooling: Forced Convection

Standards

  • EN 61000-6-2,4*: Electromagnetic compatibility Immunity & Emission standards for industrial environments
  • 2006/95/EC *: Low Voltage Directive
  • ISO 1540: Characteristics of aircraft electrical system
  • ISO 6858: Aircraft ground support electrical supplies
  • SAE ARP 5015: Ground equipment 400Hz ground power performance requirement
  • MIL-STD-704F: Aircraft electric power characteristics
  • MIL-STD-1472: Human Engineering Design Criteria
  • DFS-400: Specification for 400Hz aircraft power supply
  • *Defined Basis of CE Mark Certification
Alternate Models
UFC-45M-420UDC425 amps continuous / 2000 amps max
UFC-45M-620UDC600 amps continuous / 2000 amps max
Compatible Aircraft*
ATR42, 72
AdamA500, A700
AerospatialeNord 262
AgustaAW139 (AB139)
Airbus Military (CASA)212-100, 212-200, C-295, CN-235/HC-144A
BAeJetstream 31, Jetstream 41
Bell204, 205, 206B3, 206L4, 206LT, 212, 214, 214ST, 222, 230, 407, 412, 427, 430, 525, CH-139, OH-58, TH-67, UH-1, UH-1H
Bombardier (Business)C-21, Challenger 300, Challenger 350, Challenger 600, Challenger 601, Challenger 604, Challenger 850, Challenger 870, Challenger 890, Global 5000, Global Express, Learjet 23, Learjet 24, Learjet 31, Learjet 31A, Learjet 35, Learjet 45, Learjet 55, Learjet 60, Learjet 70, Learjet 75
Bombardier (Regional)CRJ100, CRJ1000, CRJ200, CRJ700, CRJ705, CRJ900, Dash 6 (Twin Otter UV-18A), Dash 7, Dash 8-100, Dash 8-200, Dash 8-300, Dash 8-400
Britten NormanIslander/Trislander
Cessna402, Bravo, Caravan 208, Caravan 208B, Caravan 406, Citation 560 XL, Citation 560 XLS, Citation 650, Citation CJ1, Citation CJ2, Citation CJ3, Citation Encore 560, Citation I 500, Citation I/SP 501, Citation II 550, Citation III, Citation IV, Citation M2, Citation SII, Citation Sovereign 680, Citation Ultra 560, Citation V, Citation VI, Citation VII, Citation X 750, Latitude 680A, Mustang 510
DassaultFalcon 10-100, Falcon 20-200, Falcon 2000, Falcon 2000EX, Falcon 50, Falcon 50EX, Falcon 7X, Falcon 8X, Falcon 900, Falcon 900EX
Eclipse500
EmbraerEMB-110, EMB-120, ERJ-135, ERJ-140, ERJ-145, Legacy 450, Legacy 500, Legacy 600, Legacy 650, Phenom 100, Phenom 300
EurocopterAS330 Puma, AS365N Dauphin, BK-117, BO-105
Fairchild/DornierMetro Merlin III, Metro Merlin IV
Fokker28, 50, 70
General DynamicsConvair 580, Convair 600, Convair 640
GulfstreamG350, G450, G500, G550, G650, II, III
Hawker BeechcraftBeech 1900, Beech 99, Beechjet 400A, C-12, Diamond, Hawker 1000, Hawker 4000 (Horizon), HS-125 400 Series, HS-125 800 / 850 / 900 Series, King Air, Premier, T-1 Jayhawk, T-400, T-6A Texan II
HondaJetHA-420 HondaJet
IAIAstra, Westwind 1, Westwind 2
LockheedJetstar C-140
PiaggioP-180 Avanti
PilatusPC-12, PC-9
Saab2000, 340
Sabreliner40 Series, 60 Series, 70 Series
Shorts330, 360
SikorskyCH-148, H-92 Superhawk, S-65 (CH53, HH53, MH53, Sea Stallion), S-76 (AUH-76), S-92
Sino SwearingenSJ30-2
*This list is for general reference only and may not be entirely acurate for all aircraft. Please confirm all equipment meets the requirements of your aircraft with the owners/maintenance manuals prior to purchasing or using with your aircraft.
CUSTOMER REVIEWS
5/5
by
Unit performs as expected. Using it on a GVII-G500. Unit is a lot more quiet than most the GPU's. Ordering process and changes to quote were very easy to do.