Discontinued or No longer available
This item has been discontinued or is no longer available.
It has been replaced by Unitron UDC-420M
CofC and 8130 available at no cost
Worldwide shipping available
Foxcart's line of upgraded FDC units features analog gauges, voltage regulation, upgraded warranty, and new cart design.
Standard Features:
- IP55
- Certified to UL 1012
- Indoor/Outdoor Use - (Repair Shop/Ramp Area)
- Limited 3 Year Factor Warranty
- Emergency Power “OFF” Switch
- Output Voltage and Current Monitoring
- Front Panel Summary Fault Indicators
- Input/Output Cable Handle Storage
- Output Current Meter Scale Select
Input:
-
Input Voltage: 208-240V and 380-480V, ± 10% 3Ø, 3 or 4 wire plug ground (Specify manual tap setting at time of order)
- Frequency: 50 - 60 Hz +/- 10%
- Protection: Over/under voltage, loss of phase, overcurrent, short circuit. Voltage transient protection IAW IEEE C62.41.1, Location Cat. B/C
- Inrush Current: No greater than 100% of full load current
Environmental:
- Acoustical Noise: < 65 dBA maximum at 5 feet (1.5m)
- Temperature Range: -40°C to +55°C
- EMI/RFI: Compatible with aircraft systems
- Relative Humidity: 0 - 95%, Non-Condensing
- Ingress of Water: IP55
Output:
- Full Rated Load: 425 amps continuous
- Engine Start Capacity: Adjustable up to 1600 amps for 30 seconds
- Voltage: 28 VDC, 2 wire, grounded negative
- Protection: Overload, short circuit, over-voltage, and optional safety disconnect
Voltage Regulation:
- 100% continuous rated load and +/- 10% input voltage: +/- 0.5%
- No-load to rated load with nominal input voltage: +/- 0.5%
- Overload with nominal input voltage: See start mode curves
Standards:
- NFPA 70 (NEC 500)
- EN 60079-10
- ISO 461-1/2
- ISO 1540
- ISO 6858
- UFGS 26 35 43
- MIL-STD-1472
- MIL-STD-704F
Mechanical Specifications:
- Size: See the image on the listing
- Weight: 260lbs. (118kg.) ***for base model, varies with options
- Enclosure: NEMA 250 - Type 3SX
- Cooling: Forced Air
Available Options
***Priced separately. Please request at time of quote.
- Alternate 3Ø, 60Hz Input Voltage Range 575 - 600VAC Available
- Various Convenience Outlets (Specify Voltage & Frequency)
- 50 to 150-foot Input Power Cable (Pigtail or Connector - Specify)
- 9 or 12 Inch Top Cable Storage Rack
- DC Output Power Cable with Plug (Available in 20, 30, 45 ft. lengths)
- Output Safety Interlock Circuit Disconnect
- Custom Paint & Decals (Standard Color - Yellow)
- Lockable Front Door
- CSA Certified
- Maintenance Free Wheel Kit
- 18" Safety Cart - Required for Hangar Operation
- Internal Elapsed Time Meter
| General Information | |
|---|---|
| Part # | FDC-420M |
| Manufacturer | Foxcart |
| Shipping Information | |
|---|---|
| Freight NMFC | 61700 |
| Schedule B | 8504409540 |
| ECCN | EAR99 |
Customers also viewed
AIRCRAFT COMPATIBILITY
| Compatible Aircraft* |
|---|
*This list is for general reference only and may not be entirely accurate for all aircraft. Please confirm all equipment meets the requirements of your aircraft with the owners/maintenance manuals prior to purchasing or using with your aircraft.
PRODUCT REVIEWS
This item does not have any reviews yet.
QUESTIONS & ANSWERS
There are no questions yet. Be the first to ask.