Bug Season Is Here. Shop Real Clean Bug Remover

Menu

G-246AT - Gill G-246 24V 19Ah Dry Charged Battery

Item Superseded
This item has been discontinued or is no longer available.

It has been replaced by Teledyne Gill 7246-20 (Qty 1)

Free Ground Shipping
Shipping Offers

Free shipping promotion applies to orders in the continental United States, excluding Alaska and Hawaii.

Specific Part Number

The G-246AT is a specific part number of the series Teledyne Gill G-246. For more generalized information on this item series or for more options, click here.

CofC and 8130 available at no cost
Worldwide shipping available
Ask Our Aviation Specialists
Live Chat | +1.252.585.4553 | Email

Need a Quote?

Use this form to get a quote by email today.
First Name:*
Last Name:*
Email:*
Company Name: (optional)
Questions/Comments: (optional)
Air Tractor Part Number - Same as G-246
Alternate Models
G-246ATAir Tractor Part Number - Same as G-246
PS12-24P11Previous Gill Battery Part Number
General Information
Part #G-246AT
ManufacturerTeledyne Gill
Spec Sheet 1View Spec Sheet
MSDS 1View Safety Data Sheet
Shipping Information
Product Weight36 lbs.
Product Dimensions11 x 8 x 10 in.
Schedule B8507200090
ECCN9A991.d

Customers also viewed

Teledyne Gill 7246-20
Sealed VRLA for Cessna 310/404, Piper Navajo, and Air Tractor ag aircraft. FAA-PMA certified, 18-month first inspection interval.
Teledyne Gill G-242
Activate with electrolyte before installation. For Cessna 172/182, Piper Navajo. VRLA sealed upgrades: 7242-14 or 7242-16.
Teledyne Gill G-243
Activate with electrolyte before installation. For Cessna 172/182, Piper Warrior. VRLA sealed upgrades: 7243-14 or 7243-16.
Teledyne Gill G-25
Activate with electrolyte before installation. For Cessna 172, Piper Cherokee, and light GA. VRLA upgrades: 7025-20 or 7025-24.
Teledyne Gill G-35
Activate with electrolyte before installation. For Cessna 182, Beechcraft Bonanza. VRLA upgrades: 7035-28 or 7035-34.

Customers who bought this item also purchased

Teledyne Gill 53055
1.285 SG battery-grade electrolyte. Two 1-quart bottles for activating Gill G-series dry charged aircraft batteries.
Teledyne Gill 53056
1.285 SG battery-grade electrolyte. Three 1-quart bottles for activating Gill G-series dry charged aircraft batteries.

AIRCRAFT COMPATIBILITY

Compatible Aircraft*
Air Tractor AT-300 , AT-302 , AT-400 , AT-402 , AT-402A , AT-402B , AT-502 , AT-502A , AT-502B , AT-503A , AT-602 , AT-802 , AT-802A
Piper Aztec , Navajo
*This list is for general reference only and may not be entirely accurate for all aircraft. Please confirm all equipment meets the requirements of your aircraft with the owners/maintenance manuals prior to purchasing or using with your aircraft.

PRODUCT REVIEWS

This item does not have any reviews yet.

QUESTIONS & ANSWERS

Question:
How do I activate my Gill G-246 battery?
Answer:

To activate your Gill G-246 dry-charged battery, begin by removing the sealing caps from each cell. Carefully fill each cell with the appropriate sulfuric acid electrolyte. It’s crucial to use the correct electrolyte to achieve the desired battery performance.

After filling, allow the battery to sit undisturbed for approximately 15 to 30 minutes. This soaking period enables the electrolyte to fully saturate the dry-charged plates, ensuring efficient chemical reactions during charging.

Following the soaking period, charge the battery using a constant current charger set to the manufacturer’s recommended rate. Monitor the battery’s temperature during charging, ensuring it does not exceed 125°F (52°C). If the temperature approaches this limit, reduce the charging rate or temporarily halt the process to allow the battery to cool.

Once charging is complete, verify that the electrolyte levels are within the specified range, topping up if necessary. Securely replace the sealing caps and clean any spilled electrolyte from the battery’s exterior to prevent corrosion.

Asked January 14, 2025
Question:
Is it okay to add electrolyte to the Gill G-246 battery after the initial conditioning?
Answer:

No, adding electrolyte after the initial conditioning is not recommended. Introducing additional electrolyte can disrupt the chemical balance within the battery cells, leading to increased voltage and reduced battery life.

Asked January 14, 2025
Question:
Can I partially charge my Gill G-246 battery today and finish charging it tomorrow?
Answer:

Yes. Gill aircraft batteries do not have any “memory effect,” so interrupting the charge will not harm them. Just be sure to turn off your battery charger when pausing the process. For optimal performance, it’s best to finish charging your battery within the same day.

Asked January 14, 2025
Question:
Can I charge my Gill G-246 battery while the aircraft is on the ground?
Answer:

Gill does not recommend onboard battery charging. Always remove the battery from the aircraft before charging.

Asked January 14, 2025
Question:
How often should the Gill G-246 battery be changed?
Answer:

If properly serviced, your Gill G-246 battery can provide several years of reliable service. However, Gill recommends changing your battery every two-and-a-half to three years.

Asked January 14, 2025
Question:
What is good battery voltage on a new, fully charged Gill G-246 battery?
Answer:

On a newly charged 24V battery like the G-246, the voltage should read 26 to 26.4 volts.

Asked January 14, 2025
Question:
How should I store my Gill G-246 battery when not in use?
Answer:

Store the battery in a cool, dry place with a stable temperature, ideally around 80°F (27°C). Avoid exposure to extreme temperatures, as this can adversely affect the battery’s condition. Ensure the storage area is well-ventilated and away from flammable materials. Additionally, store the battery upright to prevent any potential leakage.

Before storage, wipe the battery with a dry cloth to remove any dirt or moisture that could lead to terminal corrosion and ensure the battery is fully charged. A fully charged battery is less susceptible to sulfation, a condition that can diminish performance. Even during storage, it's important to check the battery's voltage periodically. If the voltage drops below 75% of its state of charge, recharge the battery to prevent deep discharge, which can shorten its lifespan.

Asked January 14, 2025
Question:
What is the shelf life of the Gill G-246 battery?
Answer:

Gill dry-charged lead-acid batteries, including the G-246, are designed to be stored for extended periods before activation. When stored under optimal conditions – specifically in a cool, dry environment with temperatures around 80°F (27°C) – these batteries can maintain their charge for several years. 

However, it’s essential to monitor the open-circuit voltage periodically during storage. If the voltage drops below 75% of its state of charge, recharging is recommended to prevent sulfation and ensure optimal performance upon activation. Proper storage and maintenance practices are crucial to preserving the battery's shelf life and readiness for use.

Asked January 14, 2025
Question:
What is the warranty on the Gill G-246 battery?
Answer:

Gill G-246 dry-charged lead-acid batteries are warranted for a period of 12 months or 600 hours of operation, whichever occurs first, after the date of installation. Teledyne Battery Products (TBP) will replace any battery manufactured by it which, within the applicable 15 months or 900-hour period, is found to the satisfaction of TBP to be defective in material or workmanship.

Asked January 14, 2025
Question:
What maintenance is required for the Gill G-246 battery?
Answer:

Proper maintenance of Gill dry-charged lead-acid aircraft batteries is essential to ensure optimal performance and longevity. Key maintenance practices include:

  • Regular Inspections: Periodically inspect the battery for signs of physical damage, corrosion, or electrolyte leakage. Ensure that all connections are clean, tight, and free from corrosion.
  • State of Charge Monitoring: Regularly check the battery's open-circuit voltage to assess its state of charge. Maintaining a full charge helps prevent sulfation, which can impair battery performance.
  • Proper Charging: Use a charger compatible with lead-acid batteries and follow the manufacturer's recommended charging procedures. Avoid overcharging or undercharging, as both can reduce battery lifespan.
  • Electrolyte Level Maintenance: For batteries with accessible cells, periodically check electrolyte levels and top up with distilled water if necessary. Do not add electrolyte after the initial filling, as this can alter the chemical balance and harm the battery.
  • Storage Considerations: If storing the battery for extended periods, ensure it is fully charged and kept in a cool, dry environment. Regularly monitor the state of charge during storage and recharge as needed to prevent deep discharge.
Asked January 14, 2025