Create yours now for free.
Need a Quote?
The Laversab Model 6150 Digital Air Data Leak Tester is a rugged, purpose-built solution designed exclusively for performing precision leak checks on an aircraft’s Pitot and Static systems. Engineered to meet the needs of technicians working across all aircraft types, from general aviation to commercial and military fleets, the 6150 provides reliable, real-time data for altitude, airspeed, and vertical speed simulations, helping ensure the airtight integrity of critical flight systems. With a focus on safety, accuracy, and ease of use, this tester combines advanced leak detection capabilities with built-in protections to safeguard onboard instruments during testing.
Key Features
-
Simulates altitude, airspeed, and vertical speed to verify the integrity of Pitot-Static systems
-
Performs dedicated leak checks with real-time display of results at 1, 3, and 5-minute intervals
-
Leak resolution down to 1 ft/min or 0.001 inHg/min, ideal for pinpoint diagnostics
-
Connects directly to aircraft Pitot and Static ports, no adapters or conversion kits required
-
Multiple units of measure: feet, meters, knots, km/h, inHg, and mbar for global compatibility
-
Static pressure range from 1.0 to 32 inHg with high precision (±0.008 inHg)
-
Altitude simulation range from -2,000 to 50,000 feet with 1 ft resolution and ±24 ft accuracy at 35,000 ft
-
Pitot pressure range from 1.0 to 60 inHg, supporting airspeed simulation up to 500 knots
-
Accurate airspeed readings: ±2.0 knots @ 50 knots, improving to ±0.2 knots @ 500 knots
-
Climb/descent simulation up to ±10,000 ft/min with 1 ft/min resolution and ±1% accuracy
-
Aircraft protection features prevent over-pressurization and reduce risk of instrument damage
-
Operates on 90–260 VAC input, 47-440 Hz, drawing just 50 VA
-
Lightweight and portable: measures 22" x 14" x 9" and weighs only 18 lbs
-
Durable for field use with wide environmental specs:
– Operating temp: 0°C to 50°C
– Storage temp: –40°C to 75°C
– Humidity tolerance: 5% to 100%
STATIC PORT
Pressure Function
- Range: 1.0 to 32 inHg
- Resolution: 0.001 inHg
- Accuracy: ±0.008 inHg
- Units: inHg mbar
Altitude Function
- Range: -2000 ft to 50,000 ft
- Resolution: 1 ft
- Accuracy: ± 24 ft @ 35,000 ft
- Units: feet, meters
Climb Function
- Range: 0 ft/min to ±10,000 ft/min
- Resolution: 1 ft/min
- Accuracy: ±1% of rate of climb
- Units: ft/min, meters/sec
PITOT PORT
Pressure Function
- Range: 1.0 to 60 inHg
- Resolution: 0.001 inHg
- Accuracy: ±0.008 inHg
- Pt Units: inHg, mbar
Airspeed Function
- Range: 0 to 500 knots
- Resolution: 0.1 knots
- ± 2.0 knots @ 50 knots
- ± 1.0 knots @ 100 knots
- ± 0.5 knots @ 200 knots
- ± 0.2 knots @ 500 knots
- Units: knots, km/hr
- Rate of change: 0 to 500 knots/min
Leak Check Function
- Resolution: 1 ft/min; 0.001 inHg/min
Whether you’re maintaining regional jets, helicopters, or business aircraft, the Laversab 6150 delivers accurate, dependable leak testing in a compact, easy-to-deploy package. Designed for reliability and trusted by maintenance professionals, it’s the essential tool for safeguarding flight performance from the ground up.
| General Information | |
|---|---|
| Part # | 6150 |
| Manufacturer | Laversab |
AIRCRAFT COMPATIBILITY
| Compatible Aircraft* |
|---|
PRODUCT REVIEWS
This item does not have any reviews yet.
QUESTIONS & ANSWERS
There are no questions yet. Be the first to ask.