05-7044-1210 - Tronair 5110 / 5111 Hydraulic Power Unit (HPU)
The 05-7044-1210 is a specific part number of the series Tronair 5110. For more generalized information on this item series or for more options, click here.
| Alternate Models | |
|---|---|
| 05-3005-1100 | Previous Model Number |
| 05-3005-1200 | Previous Model Number |
| 05-7014-1200 | Previous Model Number to 5110 Tronair HPU |
| 05-7015-1100 | Previous Model Number |
| 05-7044-1210 | Previous Model Number |
| 51100AB3 | 0 - Desert Sand AB - KHC-1005 Aircraft Couplers 3 - 440 -480V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included |
| 51101AA0 | 5 - HPU 1 - 6 GPM / 3000 PSI / 5 HP 1 - MIL-PRF-5606 0 - Standard 1 - Tronair Blue AA - KHC-1004 Couplers 0 - 208V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included Standard Features: 15 ft Hoses Single System |
| 51101AA1 | KHC-1004 Couplers, 220-240V 3 PH 60 HZ Input Voltage |
| 51101AA1FKW | 5 - HPU 1 - 6 GPM / 3000 PSI / 5 HP 1 - MIL-PRF-5606 0 - Standard 1 - Tronair Blue AA - KHC-1004 Couplers 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included F - Hourmeter K - Pyrometer W - Return Filter Standard Features: 15 ft Hoses Single System |
| 51101AA7 | KHC-1004 Couplers, 380V 3 PH 50 HZ Input Voltage |
| 51101AB3 | KHC-1005 Couplers, 440-480V 3 PH 60 HZ Voltage, Single System |
| 51101AB6 | KHC-1005 Aircraft Couplers, 220-240V 50 HZ Input Voltage |
| 51101AN1 | KHC-1015 Couplers, 220-240V 3 PH 60 HZ Input Voltage |
| 51101AV6 | KHC-1075 Eurocopter 105 Couplers, 220-240V 3 PH 50 HZ Input Voltage |
| 51101AV7 | KHC-1075 Eurocopter 105 Couplers, 380-400V 3 PH 50 HZ Input Voltage |
| 51101EB3AAC | KHC-1005 Aircraft Couplers, Dual System, 440-480V 3 PH 60 HZ Input Voltage |
| 51101EB6C | KHC-1005 Couplers, 220-240V 50 HZ Input Voltage, Dual System |
| 51101EV0DFM | 5 - HPU 1 - 6 GPM / 3000 PSI / 5 HP 1 - MIL-PRF-5606 0 - Standard 1 - Tronair Blue EV - KHC-1075 Eurocopter 105 Couplers for Split System 0 - 208V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included D - Split System (Dual) with Cross Over Check F - Hourmeter M - Hand Pump Standard Features: Single System 15 ft Hoses |
| 51101EV1DFM | 5 - HPU 1 - 6 GPM / 3000 PSI / 5 HP 1 - MIL-PRF-5606 0 - Standard 1 - Tronair Blue EV - KHC-1075 Eurocopter 105 Couplers for Split System 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included D - Split System (Dual) with Cross Over Check F - Hourmeter M - Hand Pump Standard Features: 15 ft Hoses |
| 51101EV9C | EV - KHC-1075 Eurocopter 105 Couplers 9 - 440V 3 PH 50 HZ Input Voltage Required / 50' AC Input Cable Included C - Split (Dual) System |
| 51101EX6C | KHC-1084 Couplers, 220-240V 50 HZ Input Voltage, Dual System |
| 51101FR1C | FR - KHC-2257 Aircraft Couplers (Split System) 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included C - Split System (Dual) |
| 51101FR3C | KHC-2257 Couplers, Dual System, 440-480V 3 PH 60 HZ Input Voltage |
| 51101FR8CK | KHC-2257 Couplers, 415V 3 PH 50 HZ, Dual System, Pyrometer |
| 51101ZZ1 | No Aircraft Couplers - 220-240V 3 PH 60 HZ Input Voltage |
| 51101ZZ1ADFM | ZZ - No Aircraft Couplers Included 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included A - 25 ft Hoses D - Split System with Crossover Check F - Hourmeter M - Hand Pump |
| 51101ZZ3 | ZZ - No Aircraft Couplers 3 - 440V-480V 3 PH 60 HZ Input Voltage / 50' AC Input Cable Included |
| 51201ZZ1 | Can be converted to use with 5606 fluid |
| General Information | |
|---|---|
| Part # | 05-7044-1210 |
| Manufacturer | Tronair |
AIRCRAFT COMPATIBILITY
| Compatible Aircraft* | |
|---|---|
| Agusta | A109A , A109C , A109E , A109S , Mark II |
| BAe | Jetstream 31 , Jetstream 41 |
| Bombardier | C-21 , Learjet 23 , Learjet 24 , Learjet 25 , Learjet 31 , Learjet 31A , Learjet 35 , Learjet 55 , Learjet 60 |
| Dassault | Falcon 10-100 |
| Embraer | EMB-110 , EMB-120 |
| Eurocopter | AS330 Puma , BK-117 , BO-105 |
| Fairchild/Dornier | Dornier DO328 , Dornier DO328 Jet , Envoy 3 |
| Hawker Beechcraft | 300 - King Air , Hawker 1000 , HS-125 400 Series , HS-125 800 / 850 / 900 Series , King Air , T-1 Jayhawk , T-400 , T-6A Texan II |
| Let Kunovice | L-410 Turbolet |
| Pilatus | PC-12 , PC-9 |
| Sabreliner | 40 Series , 60 Series , 70 Series |
| Shorts | 330 , 360 |
PRODUCT REVIEWS
This item does not have any reviews yet.
QUESTIONS & ANSWERS
No, the 5110 series cannot be manufactured with CE compliance. If CE compliance is needed, you will need to purchase a 52 series HPU.
No. The engineers at Tronair have confirmed that the 5110 HPU will not have 100' cords available as an option.
Standard features for the Tronair 5110 Series HPU include:
- 15' Hoses
- Single System
- 50' Input Cable (Only)
- 10-Gallon Reservoir
Available options for the 5110 Series HPU include:
- 25' Hoses (Option A)
- Split System (Option C)
- Split System with Crossover Check (Option D)
- Hourmeter (Option F – 50 Hz and 60 Hz)
- Pyrometer (Option K)
- Hand Pump (Option M)
- Return Back-Pressure with Sight Gauge (Option T – Skydrol Only)
- Return Filter (Option W)
Tronair 5110 Series HPUs can be set for 200V to 460V 3-phase input voltage at either 50 or 60 Hz. Since these units are custom-built, this information is required upfront to complete them.
The pressure hose for the 5110 Series HPU is TF-1037-01*180, and the return hose is TF-1039-01*180.