05-7023-1200 - Tronair 5220 / 5221 Hydraulic Power Unit (HPU)
Create yours now for free.
The 05-7023-1200 is a specific part number of the series Tronair 5220. For more generalized information on this item series or for more options, click here.
Need a Quote?
| Alternate Models | |
|---|---|
| 05-7023-1100 | Previous Alternative Model Number |
| 05-7023-1200 | Previous Alternative Model Number |
| 52111BV1FKQ4 | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 1 - MIL-PRF-5606 1 - CE Compliant 1 - Tronair Blue BV - KHC-2407 Aircraft Couplers 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included F - Hourmeter (60 HZ) K - Pyrometer Q - Calibration Port 4 - Drip Pan Standard Features: 15 ft Hoses Single System |
| 52111ZZ8 | Single System, No Couplers, 415V 3 PH 50 HZ |
| 52201EA7D | Dual System with Crossover Check, KHC-1004 Couplers, 380-400V 3 PH 50 HZ |
| 5221 | CE Compliant Version |
| 52210EA3BBCFK | Dual System, 50 ft hoses, Hourmeter, Pyrometer, KHC-1004 Couplers, 440-480V 3 PH 60 HZ, CE Compliant |
| 52211AB1 | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue AB - KHC-1005 Aircraft Couplers 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included Standard Features: 15 ft Hoses Single System |
| 52211EA1AACFKNRS4 | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue EA - KHC-1004 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included AA - 25' Hoses C - Split (Dual) System F - Hourmeter (60 HZ) K - Pyrometer N - Towing / Trailer Package R - Electric filter clogged indicator S - Electric over temperature 4 - Drip Pan |
| 52211EA1CF | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue EA - KHC-1004 Aircraft Couplers 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included C - Dual System F - Hourmeter (60 HZ) Standard Features: 15' Hoses - 2 Sets (Dual System) |
| 52211EA1D | Dual System w/Crossover Check, KHC-1004 Couplers, 220-240V 3 PH 60 HZ Voltage |
| 52211EA4D | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIl-PRF-83282 1 - CE Compliant 1 - Tronair Blue EA - KHC-1004 Couplers 4 - 575V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included D - Dual System w/ Crossover Check Standard Features: 15 ft hoses (2 sets) |
| 52211EA6C | Dual System, KHC-1004 Couplers, 220-240V 3 PH 50 HZ Input Voltage, CE Compliant |
| 52211EA7 | 5 - HPU 2 - 8 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue EA - KHC-1004 Couplers 7 - 380-400V 3 PH 50 HZ Input Voltage Required / 50' AC Input Cable Included Standard Features: 15 ft Hoses Single System |
| 52211EA7C | 5 - HPU 2 - 8 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue EA - KHC-1004 Couplers 7 - 380-400V 3 PH 50 HZ Input Voltage Required / 50' AC Input Cable Included C - Dual system Standard Features: 15 ft Hoses (Qty 2) |
| 52211EB0C | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue EB - KHC-1005 Coupling Kits 0 - 208V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included C - Split (Dual) System Standard Features: 15 ft Hoses (Qty 2) |
| 52211EB1C | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue EB - KHC-1005 Coupling Kits 1 - 220-240V 3 PH 60 HZ Input Voltage Required / 50' AC Input Cable Included C - Split (Dual) System Standard Features: 15 ft Hoses (Qty 2) |
| 52211FF3C | 5 - HPU 2 - 10 GPM / 3000 PSI / 15 HP 2 - MIL-PRF-83282 1 - CE Compliant 1 - Tronair Blue FF - KHC-1306 3 - 440V-480V 3 PH 60 HZ Input Voltage / 50' AC Input Cable C - Split (Dual) System Standard Features 15 Ft Hoses (2 Sets) |
| 52211KQ2BF | KQ - Coupling Kit 2 - 380V 3 phase 60 HZ / 50' Input Cable Included B - 50' Hoses F - Hourmeter |
| General Information | |
|---|---|
| Part # | 05-7023-1200 |
| Manufacturer | Tronair |
AIRCRAFT COMPATIBILITY
| Compatible Aircraft* | |
|---|---|
| Bell | 206B3 , 206L4 , 206LT , OH-58 , TH-67 |
| Boeing | Apache AH-64 |
| Eurocopter | AS365N Dauphin |
| Sikorsky | UH-60 Black Hawk, MH-60S Seahawk |
PRODUCT REVIEWS
This item does not have any reviews yet.
QUESTIONS & ANSWERS
Tronair 5220/5221 Series HPUs can be set for 200V to 460V 3-phase input voltage at either 50 or 60 Hz. Since these units are custom-built, this information is required upfront to complete them.
The replacement pressure hose for the 5220/5221 Series HPU is TF-1037-01*180, and the return hose is TF-1039-01*180.
Standard features for the Tronair 5220/5221 Series HPU include:
- 15' Hoses
- Single System
- Return Filter
- 30-Gallon Reservoir
Available options for the Tronair 5220/5221 Series HPU include:
- 25' Hoses (Option A/AA)
- 50' Hoses (Option B/BB)
- Split System (Option C)
- Split System with Crossover Check (Option D)
- Hourmeter (Option E/F – 50 and 60 Hz)
- Voltage Monitor (Option G-J – Voltage-Dependent)
- Pyrometer (Option K)
- Electrical Reservoir Level (Option L)
- Hand Pump (Option M)
- Towing/Trailer Package (Option N)
- Reservoir Return (Option P)
- Calibration Port (Option Q)
- Electrical Filter Clogged Indicator (Option R)
- Electric Over-Temperature (Option S)
- Return Back-Pressure with Sight Gauge (Option T – Skydrol Only)
- Return Sight Gauge (Option U/Y)
- Return Back-Pressure (Option V/1)
- Return Filter (Option W)
- 50' Hand Pump (Option X)
- Drip Pan (Option 4)
- Hand Pump (Large Displacement) (Option 7)
- Pressure-Reducing Valve (Split System) (Option 8)
- 100' Input Cable
The Tronair 5220/5221 Series hydraulic power unit operates at approximately 80 decibels under standard load conditions. This sound level is comparable to city traffic or a household vacuum cleaner and is considered moderate for equipment in the ground support category.
Operators working near the unit during prolonged use may benefit from wearing hearing protection, especially in enclosed or echo-prone environments. The unit’s acoustic profile is engineered to balance performance with noise control, making it suitable for ramp and hangar use without excessive disruption.