SPECIFICATIONS
- IP55 Rated for Dust and Water Resistance
- Certified to UL 1012
- 3-Phase, 380V to 480V AC Input (other 3-phase input voltages available upon request)
- Indoor/Outdoor Use – Hangar/Ramp
- <= 5% Input Current Distortion
- Automatic Input Line Monitoring
- Advanced Integrated Display (AID) Console
- 8,000 Event Log/Diagnostics
- TCP/IP/Ethernet interface (Modbus)
- Internal Communication Ports: USB, RJ45 (Ethernet), RS485 (Modbus), & RS232
- External Communication Ports: RJ45 (Ethernet) & USB
- 15% Automatic Line-Drop Compensation
- Emergency Power "OFF" Switch
- 18" Hazard Area Clearance
- I/O Voltage, Current, & Frequency Monitoring
- Elapsed Time Meter
- Sleep Mode
- Front Panel Summary Fault Indicators
- Input & Output Cable Racks
- Input High Voltage Transient Protection
- Multi-Language (Romanization) Display: English, French, German, Italian, Portuguese, Russian, Spanish, and Others (Request at the time of quote)
INPUT
- Input Current Distortion: <= 5%, typically 3%
- Input Voltage: 380V to 480 V, +10%, -15%, 3- or 4-Wire Plus Ground (Alternate voltages – request at time of quote)
- Frequency: 50 to 60 Hz +/- 10%
- Phase Rotation: Any
- Protection: Overvoltage/Undervoltage, Loss of Phase, Overcurrent, Short Circuit. Voltage-Transient Protection IAW IEEE C62.41.1, Location Cat. B/C
- Inrush Current: No Greater Than 100% of Full Load Current
ENVIRONMENTAL
- Acoustical Noise: < 65 dBA Maximum at 5 ft. (1.5m)
- Temperature Range: -40°C to 55°C
- Relative Humidity: 10% to 95%
- Ingress of Water: Type 3RX, IP55
ENERGY FACTORS
- Efficiency: 93% Typical at Full Load, 90% Typical at Half Load; Varies Depending on Configuration
- Energy Efficiency Ratio: 20.0 Typical
OUTPUT
- Overload: 100% Continuous, 110% for 60 Min., 125% for 10 Min., 150% for 2 Min., 200% for 20 Sec. (45kVA)
- Voltage: 115/200 Volts, 3-Wire, 4-Wire, Grounded Neutral
- Crest Factor: 1.414 +/- 3%
- Voltage Regulation: +/- 1.0% Under All Conditions of Line, Balanced Loads, and Temperature
- Voltage Transients: IAW MIL-STD-704F
- Frequency Regulation: 400 Hz +/- 0.01% Under All Conditions of Line, Load, and Temperature
- Frequency Transients: None
- Phase Angle Regulation: +/- 1° for Balanced Loads; +/- 2° for Unbalanced Loads
- Harmonic Distortion: 2.0% Maximum
- Protection: Overload, Short Circuit, Overvoltage/Undervoltage, and Safety Disconnect
- Automatic Line-Drop Compensation (ALDC): 15%
CABINET INFO
- Weight: 637 lbs. (289 kg)
- Length: 40" (1,015 mm)
- Width: 33" (838 mm)
- Height: 45" (1,138 mm)
- Enclosure: NEMA 3RX Corrosion-Resistant
- Cooling: Forced Convection
STANDARDS
- EN 61000-6-2*: Electromagnetic Compatibility, Immunity Standard for Industrial Environments
- EN 61000-6-4*: Electromagnetic Compatibility, Emission Standard for Industrial Environments
- 2006/95/EC*: Low-Voltage Directive
- ISO 1540: Characteristics of Aircraft Electrical System
- ISO 6858: Aircraft Ground Support Electrical Supplies
- SAE ARP 5015: Ground Equipment 400 Hz Ground Power Performance Requirement
- MIL-STD-704F: Aircraft Electric Power Characteristics
- MIL-STD-1472: Human Engineering Design Criteria
- DFS-400: Specification for 400 Hz Aircraft Power Supply
*Defined Basis of CE Mark Certification
AVAILABLE OPTIONS
**If any options below are required, please request them at the time of the quote.
- Alternate Input Voltage Range: 3-Phase, 208V to 240V or 600V AC input
- 50' or 100' Input Power Cable – Pigtail (specify required length)
- AC Output Power Cable with Plug – Available in 30' or 60' Standard Lengths (specify required length)
- Output Universal Aircraft Safety Interlock Circuit Disconnect (single or dual)
- Output Safety Disconnect
- Front Panel AC Voltage Adjust (+/- 15%)
- 28V DC or 270V DC Output
- Up to 675% Overload for 6 Seconds, Dependent on Rating
- No Break Power Transfer (NBPT) Compatible
- Indoor Touch Screen Panel
- Alternate Mounting Configurations Available
- Pneumatic Ramp Tires
- Custom Paint & Decals – Standard Color: White
- CSA Certified
- CE Mark Certified
- Ground Fault Monitor
- Lockable Front Door
- Neutral Interrupt Protection
- Universal Safety Interlock
| Alternate Models | |
|---|---|
| 45SX200 | Comparable Model Number |
| 45SX240 | Comparable Model Number |
| GFC-25M | Alternate Model Number |
| GFC-37M | Alternate Model Number |
| GFC-45M | Alternate Model Number |
| UFC-45M-575 | 575V/600V 3 phase input voltage unit |
| UFC-45M-Dual | Dual Output (380-480V 3 Phase Input Voltage) |
| UFC-45M-PJI100 | 3-Phase, 380V to 480V AC Input with 100' input/30' output cable |
| UFC-45M-T3 | Low 3 Phase Voltage Transformer Installed (208V to 220V) |
| UFC-45M-T3-Dual | Dual AC Output - Low 3 Phase Voltage Transformer Installed (208V to 220V) |
| UFC-45M-T3-PJI100 | 3-Phase, 208V to 240V AC with 100' input/30' output cable |
| ULP-045-1-LV-AC | Gulfstream Reference Number |
| General Information | |
|---|---|
| Part # | UFC-45M |
| Manufacturer | Unitron |
| Warranty | |
|---|---|
| Details | 3 Year Limited Warranty - View Details |
| Shipping Information | |
|---|---|
| Freight NMFC | 61700 |
Customers also viewed
Customers who bought this item also purchased
AIRCRAFT COMPATIBILITY
| Compatible Aircraft* | |
|---|---|
| Bombardier | Challenger 600 , Challenger 601 , Challenger 604 , Challenger 850 , CRJ100 , CRJ1000 , CRJ200 , CRJ700 , CRJ900 , Dash 8-100 , Dash 8-200 , Dash 8-300 , Dash 8-400 , Global 5000 , Global Express |
| Fokker | 28 , 50 , 70 |
| Gulfstream | G350 , G400 , G450 , G500 , G550 , G650 , II , III , IV |
| Hawker Beechcraft | Hawker 4000 (Horizon) |
| Saab | 2000 |
PRODUCT REVIEWS
Performing as advertised. We use it on our Challenger 650. Great service from CGSE. Best in the business!
Jory Sandoval
Bluesky Helicopters
#blackhawkparts
QUESTIONS & ANSWERS
The UFC-45M single-output unit should be sufficient to support either the Gulfstream G700 or the G800. If you are looking to power both aircraft simultaneously, the UFC-90M dual-output unit could accomplish this.
The Unitron UFC-45M PwrKrt stands out due to its mobile design, compact footprint, and modular construction, which makes it highly adaptable for both ramp and hangar operations. Unlike many static GPUs, it’s specifically engineered for flexibility and ease of relocation. Its compatibility with both 400 Hz and 28V DC power output configurations makes it suitable for a wide range of aircraft. Additionally, its touchscreen interface and fault-monitoring capabilities offer enhanced usability and troubleshooting.
The Unitron UFC-45M GPU includes a touchscreen control panel with real-time fault codes, output monitoring, and diagnostics. This intuitive display simplifies startup, shutdown, and troubleshooting for ground crews. The interface includes password-protected service menus to prevent unauthorized configuration changes, ensuring equipment integrity and operational safety.
The UFC-45M is engineered for low-maintenance operation, but regular inspections of filters, electrical connections, and cable integrity are recommended. The unit’s built-in diagnostics and monitoring help crews stay ahead of potential issues. Unitron provides full maintenance documentation and parts support to simplify service cycles and reduce equipment downtime.
Yes! Select models of the UFC-45M can be configured with optional remote diagnostic features. This allows maintenance teams to monitor unit status and troubleshoot issues off-site, streamlining response time and minimizing aircraft ground delays. The system can be integrated with fleet maintenance software for larger operators.
The UFC-45M complies with multiple industry standards, including MIL-STD-704F, DO-160, and ISO 9001 quality protocols. It’s CE-marked for European compliance and UL-listed for North American safety standards. These certifications ensure the GPU meets rigorous safety, electromagnetic compatibility, and environmental performance standards.