The Aerox 4110-725-002-02-1 Quick-Donning Diluter Demand Mask is a premium aviation oxygen mask built for demanding, high-altitude flight operations. Designed to meet stringent FAA requirements and approved under TSO C89A and TSO C78A, this mask ensures reliable performance and superior comfort for pilots and crew flying at altitudes up to 40,000 feet. Whether you're navigating long cross-country routes in a pressurized aircraft or preparing for potential cabin depressurization, this quick-donning mask is a critical component of any aviation oxygen system.

With its intuitive one-handed donning design, soft silicone facepiece, and rugged carbon fiber shell, this pilot oxygen mask balances comfort, safety, and ease of use. The integrated microphone keeps communication clear under pressure, and multiple fitting and hose options allow seamless integration with a wide range of general aviation and turbine aircraft.

Key Features

Built for general aviation, turbine aircraft, and jet operators, the Aerox 4110-725-002-02-1 Quick-Donning Diluter Demand Mask is the trusted choice for flight crews who demand performance and safety from their aviation oxygen equipment. Whether you’re preparing for an international trip or equipping your aircraft with FAA-compliant emergency oxygen gear, this mask delivers unmatched readiness and reliability.

General Information
Part #4110-725-002-02-1
ManufacturerAerox

Customers also viewed

Alberth TC-42
for Tires Up to 41" x 14" x 22"
Alberth GSK-500
for Gulfstream G500 Aircraft
Goodyear 145K41-1
14.5x5.5-6, 14-Ply
Aerox 4110-725-002-02-2
Medium Size, 48" Inlet Hose Length -2 PB2 (Puritan 566) Fitting
Aerox 4110-725-002-02-3
Medium, 48in Inlet Hose Length, -3 Scott Fitting (SPECIAL ORDER)

Customers who bought this item also purchased

AIRCRAFT COMPATIBILITY

Compatible Aircraft*
*This list is for general reference only and may not be entirely accurate for all aircraft. Please confirm all equipment meets the requirements of your aircraft with the owners/maintenance manuals prior to purchasing or using with your aircraft.

PRODUCT REVIEWS

This item does not have any reviews yet.

QUESTIONS & ANSWERS

Question:
What is the purpose of the Aerox 4110-725-002-02-1 quick-donning diluter demand mask?
Answer:

The Aerox 4110-725-002-02-1 mask provides pilots and crew members with a secure and efficient oxygen supply during high-altitude or emergency operations. It combines a carbon-fiber facepiece, diluter-demand regulator, and inflatable head harness that allows quick donning – typically in under five seconds – when paired with the Aerox 4110-155 stowage cup. This makes it an essential component of any aircraft’s emergency oxygen system, providing rapid response and comfort in the event of pressurization failures.

Asked October 22, 2025
Question:
How quickly can the mask be donned in an emergency?
Answer:

The inflatable head harness design enables the mask to be donned with one hand in less than five seconds when used with the Aerox stowage cup (4110-155). This rapid-deployment capability ensures that crew members can restore oxygen flow immediately after a decompression event, meeting FAA TSO requirements for time-critical safety equipment.

Asked October 22, 2025
Question:
What altitudes is the Aerox 4110-725-002-02-1 approved for?
Answer:

This Aerox diluter-demand mask is certified for operation up to 40,000 feet MSL, providing reliable performance throughout the flight envelope of most pressurized aircraft. Its regulator automatically adjusts the oxygen concentration based on cabin altitude, ensuring crew members maintain safe oxygen levels during climb, cruise, or emergency descent.

Asked October 22, 2025
Question:
What types of connectors are available for this mask model?
Answer:

Aerox offers several connector options to match different aircraft oxygen outlets. The 4110-725-002-02-1 model features a PB2-style fitting (4110-420), which mates with Aerox PB2 outlets (36728-01 and 802959-01), EROS DPB Series outlets, and select B/E Aerospace ports. Other variants in the 4110-725 series are available with PB1 and Scott connections for broader compatibility.

Asked October 22, 2025
Question:
What maintenance interval does Aerox recommend for this mask?
Answer:

Aerox recommends overhauling the quick-donning diluter demand mask every three years to maintain performance and safety certification. Regular inspections should include checking the harness inflation, microphone operation, and regulator response. Proper maintenance ensures the mask remains compliant with FAA TSO-C78a and TSO-C89a standards.

Asked October 22, 2025
Question:
Can the mask operate in extreme temperatures or humidity?
Answer:

Yes. The Aerox 4110-725-002-02-1 operates effectively within a temperature range of 20°F to 120°F (-29°C to 49°C) and in relative humidity levels ranging from 5% to 95%. However, if the aircraft is exposed to prolonged cold conditions, Aerox advises storing the mask in a warm, dry location to preserve the harness and regulator components.

Asked October 22, 2025
Question:
What are the oxygen system supply requirements for this mask?
Answer:

The Aerox 4110-725-002-02-1 requires aviation-grade oxygen (MIL-O-27210) supplied at 55 to 70 PSI (0.37 to 0.48 MPa) and a minimum flow of 100 liters per minute (NTPD). Maintaining this pressure and flow ensures consistent regulator performance and safe oxygen delivery during all phases of flight.

Asked October 22, 2025
Question:
What size and hose configuration does this model include?
Answer:

The 4110-725-002-02-1 is the medium-size mask, fitted with a 48” inlet hose for flexible crew mobility in cockpit environments. The medium size is Aerox’s most commonly stocked option, providing a secure, comfortable fit for most adult users.

Asked October 22, 2025
Question:
Does the mask include built-in communications capability?
Answer:

Yes. Each Aerox 4110-725 series mask features a built-in electret microphone with a PJ068 plug, allowing seamless integration with most aircraft intercom systems. This ensures clear voice communication even while the mask is fully sealed and operational at altitude.

Asked October 22, 2025
Question:
Why is the Aerox quick-donning mask preferred for professional crews?
Answer:

The mask’s combination of rapid deployment, lightweight carbon-fiber construction, and compatibility with multiple oxygen systems makes it a go-to choice for general, corporate, and military aviation applications. Its FAA-approved design ensures compliance, while the integrated diluter-demand regulator conserves oxygen and maintains crew safety in pressurized flight. Aerox’s three-decade heritage in aviation oxygen systems reinforces its reliability across diverse fleets.

Asked October 22, 2025