Static Output - Altitude Function
- Range: 0 ft/min to ±10,000 ft/min
- Resolution: 1 foot
- Accuracy: ±1% of rate of climb
- Units: Feet, Meters
Static Output - Altitude Rate Function
- Range: -2000 ft. to 50,000 ft.
- Resolution: 1 ft/min
- Accuracy: ± 3 ft. @ 0 ft., ± 4 ft. @ 10,000 ft., ± 6 ft. @ 20,000 ft., ± 9 ft. @ 35,000 ft., ± 18 ft. @ 50,000 ft.
- Units: Feet/min, Meters/sec
Pitot Output - Pressure Function
- Range: 0 to 15 inHg (differential)
- Resolution: 0.001 inHg
- Accuracy: +/-0.003 inHg
- Pt Units: inHg, mbar, psi, mmHg, kpa, EPR
- Units: inHg, mbar, psi, mmHg, kpa
Pitot Output - Pressure Rate
- Range: 0 to 30 inHg/min
- Resolution: 0.001 inHg
- Accuracy: ±1% of rate
- Units: pressure-units/min (EPR in inHg/min)
Pitot Output - Airspeed Function
- Range: 0 to 500 knots
- Resolution: 0.1 knots
- Accuracy: ± 1.0 knots @ 20 knots, ± 0.3 knots @ 50 knots, ± 0.2 knots @ 100 knots, ± 0.1 knots @ 200 knots, ± 0.04 knots @ 500 knots
- Units: knots, Mach, km/hr, mph
Pitot Output - Airspeed Rate
- Range: 0 to 500 knots/min
- Resolution: 0.1 knots/min (0.01 km/hr/sec)
- Accuracy: ±2% of rate
- Units: knots/min, km/hr/sec, mph/min
Pitot Output - Mach Function
- Range: 0.0 to 1.0 Mach
- Mach Resolution: 0.001
- Mach Accuracy: +/-0.001 above 0.2 Mach
Power Requirement
-
90-260 VAC, 47-440 Hz, 100 VA (200 VA with heaters) - Optional Removable Battery: 8 hours of operation
External Interfaces
- RS232 Serial ; Encoder optional
Dims and Weight
- Main unit: 22” x 14” x 9” / 28 lbs
- Remote Unit: 6” x 6” x 1” / 1 lb.
Environmental Specs
- Operating temp: 0 to 50 degree C, –40°C to 50°C (optional heater)
- Storage temp: –40°C to 75°C
- Humidity: 5 to 100%