First Name:
Last Name:
Email:
Company Name: (optional)
Do you want to buy or rent a unit?
If rental, please put in comments how long you need the unit and when do you need it?
Is the end user located in the United States?
Questions/Comments: (optional)

The Laversab 6600-NG (6600NG) automated pitot static tester is ideal for use on aircraft with SmartProbe capable of measuring AOA using air data. The NG model comes with built-in WIFI. The tester has one static output (Ps1), one pitot output (Pt) and a third output (Ps2) which can be used to simulate either AOA or AOS. Using the small and lightweight remote unit, a user can operate the tester from the cockpit and test the entire pitot and static system of the aircraft. The tester includes built-in vacuum and pressure pumps and emergency manual bleed-down valves. The high accuracy of this unit meets all RVSM requirements.

SmartProbe Aircraft

This is our “Smart Probe” box. This is RVSM as well and is used for Honda, Gulfstream G650/550, Embraer Phenom/Legacy, Dassault X series, and is pretty useful for Hawker A/C when someone needs to do a stall warning test.

Air Data Accessories Kits or Pitot/Static Adapters

View our full line of air data accessories kits or pitot/static adapters by Nav-Aids. Bundle with your new aircraft air-data pitot static tester. 

Top Features

  • Three Outputs - In addition to the primary static and pitot outputs, a third output is provided. This output can be used as a secondary static, a differential static or secondary pitot. This output allows the user to create a second altitude (in feet or meters), a second absolute pressure (in inHg or mbar), a differential pressure for simulating AOA (in Diff.inHg or Diff mbar), or a differential pressure for generating a second airspeed (in knots or kmph) to simulate AOS. When the third output is not used, the tester operates exactly like our 2-output tester (Model 6300). 
  • RVSM Compliant - The high accuracy of the tester and NIST-traceable calibration make the tester fully RVSM-compliant and suitable for use on all RVSM-compliant aircraft.
  • Automated Operation - Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within +/- 1 foot and +/- 0.1 knot.
  • Programmable Limits - User-programmable limits for altitude, airspeed, Mach, and VSI provide protection to the aircraft.
  • Jog and Hold Features - Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.
  • Ground Feature - Brings Pitot and Static outputs to ambient “ground” pressure after completing a test.
  • Profiles Feature - A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 20 profiles can be stored in the unit.
  • Leak Checks - Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of “instant” leak rates provides immediate feedback to the user. 
  • Pressure & Vacuum Source - Built-in high-capacity dual vacuum pumps and pressure pumps provide the pressure and vacuum source for the unit. The pressure system includes a filter and membrane dryer to provide clean dry air for the entire system. 
  • Remote Unit - The Remote unit is the operator interface for the tester. It is small and light enough to be used in the cockpit. The tester can be turned On and Off from the Remote. All valid parameters, including altitude, climb, and airspeed, are clearly displayed simultaneously on a single screen on the remote. 
  • Manual Vent - The tester includes precision metering valves to enable manual venting of the aircraft’s pitot-static system, in the event of power-loss. 

When is this unit used?

  • Ideal tester for use with aircraft equipped with SmartProbe™ that have the ability to sense AOA and/ or AOS. 
  • Leak-checks and Air-data-system accuracy-checks on all RVSM aircraft including aircraft with SmartProbe™. The tester can be used either in 3-output mode or 2-output mode. In 2-output mode, this tester operates exactly like our Model 6300.
  • When the 6600 is used with the OSM (Output Switching Module) it is possible to completely automate leak checks, which can be performed either individually on each port of the aircraft probes, or simultaneously on all ports. Using the OSM makes it easy to isolate leaks and the connection of the hoses and adapters to the aircraft is greatly simplified. 

Calibration Period

  • 1 Year

Static Output - Pressure Function

  • Range: 0.1 to 42 inHg
  • Resolution: 0.001 inHg
  • Accuracy: +/- 0.002 inHg
  • Units: inHg, mbar

Static Output - Altitude Function

  • Range: -4000 ft. to 60,000 ft.
  • Resolution: 1 foot
  • Accuracy: +/- 2 ft. @ 0 ft.,  +/- 6 ft. @ 35,000 ft., +/- 12 ft. @ 50,000 ft.
  • Units: Feet, Meters

Static Output - Climb Function

  • Range: 0 ft/min to +/- 25,000 ft/min
  • Resolution: 1 ft/min
  • Accuracy: +/-1% of the rate of climb
  • Units: Feet/min, Meters/sec

Pitot Output - Pressure Function

  • Range: 0.1 to 60 inHg
  • Resolution: 0.001 inHg
  • Accuracy: +/-0.003 inHg
  • Pt Units: inHg, mbar, EPR Qc
  • Units: inHg, mbar

Pitot Output - Airspeed Function

  • Range: 0 to 650 knots
  • Resolution: 0.1 knots
  • Accuracy: +/- 0.5 knots @ 50 knots,  +/- 0.25 knots @ 100 knots, +/- 0.05 knots @ 650 knots
  • Units: knots, Mach, km/hr, mph
  • Rate of change: 0 to 500 knots/min

Pitot Output - Mach Function

  • Range: 0.0 to 3.0
  • Mach Resolution: 0.001
  • Mach Accuracy: +/-0.001 above 0.2 Mach

DIFFERENTIAL OUTPUT (Referenced to Static) - Secondary Static or Pitot Output

  • Range: -30.0 to +30.0 inHg
  • Resolution: 0.001 inHg
  • Accuracy: +/-0.002 inHg
  • Units: inHg, mbar, Dfin, Dfmb, feet, mtrs, knots, kmph

Power Requirement

  • 90-260 VAC, 47-440 Hz ; 150 VA

External Interfaces

  • RS232 ; IEEE-488 & Encoder optional

Dims and Weight

  • Main unit: 22” x 14” x 9” / 40 lbs
  • Remote unit: 7” x 8” x 2” / 1 lb

Environmental Specs

  • Operating temp: 0 to 50 degree C
  • Storage temp: -25 degree C to 75 degree C
  • Humidity: 5 to 100%

6600-NG Training Video

General Information
Part #6600-NG
ManufacturerLaversab
Shipping Information
Shipping Weight55 lbs.
Shipping Dimensions30.5 x 19.5 x 16.5 in.
Schedule B9026200000
ECCN7B994