Unitron UFC-60M-420UDC – PwrKart Mobile GPU – Dual 400 Hz AC & 28V DC, 60 kVA
Create yours now for free.
Need a Quote?
The Unitron UFC-60M-420UDC PwrKart is a dual 400 Hz AC and 28V DC mobile ground power unit with a 90 kVA rating. Ideal for aircraft ground power applications in the hangar or ramp area, this lightweight GPU provides simultaneous AC and either 425 or 600 amps of continuous DC power from a single unit. Kilowatt power for the complete unit is limited to the nominal rating of the 400 Hz output of the GPU. Because a single unit can do the work of two, Unitron's AC/DC PwrKart reduces operating and maintenance costs and eases ramp congestion.
Standard Features
- IP55
- Certified to UL 1012
- 3-Phase, 50 to 60 Hz, 380 to 480V AC Input
- Indoor/Outdoor (Hangar/Ramp) Use
- ≤ 5% Input Current Distortion at max load
- Automatic Input Line Monitoring
- Advanced Integrated Display (AIDTM) Console
- 8000 Event Log / Diagnostics
- TCP/IP/Ethernet interface (Modbus)
- Internal Communication Ports: USB, RJ45 (ETHERNET), RS485 (Modbus), & RS232
- External Communication Port: USB
- 15% Automatic Line Drop Compensation
- Emergency Power “OFF” Switch
- 18” Hazard Area Clearance
- Voltage, Current, & Frequency Monitoring
- Elapsed Time Meter
- Sleep Mode
- Front Panel Voltage Adjust
- Front Panel Summary Fault Indicators
- Output Current Limit Adjusts from 150A to Full Rated Current
- Input & Output Cable Racks
- Input High-Voltage Transient Protection
- Multi-Language Display - Arabic, Asian, English, French, German, Italian, Portuguese, Russian, Spanish, and Others (Specify)
Options
- Alternate Input Voltage Range: 3-Phase, 208 to 240V or 600V AC Input
- Various Convenience Outlets (Specify Voltage and Frequency)
- 50’ or 100’ Input Power Cable (Pigtail – Specify Required Length)
- AC and/or DC Output Power Cable with Plug (Specify Required Length)
- Output Universal Aircraft Safety Interlock Circuit Disconnect (Single or Dual)
- External Communication Port: Ethernet
- Output Safety Disconnect
- No Break Power Transfer Compatible
- 270V DC Output
- Bench-Top Voltage Adjust
- Second 28V DC output
- 300% Overload for 6 Seconds or 425% Overload for 1 Second* (Specify)
- Custom Paint & Decals (Standard Color: White)
- CSA Certified
- CE Mark Certified
- Ground Fault Monitor
- Lockable Front Door
- Pneumatic Ramp Tires
- Alternate Mounting Configurations Available
- Neutral Interrupt Protection
- Universal Safety Interlock
Mechanical Specifications
- Length: 53" (1,346 mm)
- Height: 45" (1,139 mm)
- Width: 50" (1,275 mm)
- Weight: 907 lbs. (411 kg)
- Enclosure: NEMA 250 – Type 3SX
- Cooling: Forced Convection
General Specifications
AC Input:
- Input Current Distortion: ≤5% (Typically 3%)
- Voltage: 380V to 480V, +10%, -15%, 3Ø, 3-Wire or 4-Wire Plus Ground (Alternate Voltages Available)
- Frequency: 50 to 60 Hz ± 10%
- Phase Rotation: Any
- Protection: Overvoltage/Undervoltage, Loss of Phase, Overcurrent, Short Circuit. Voltage Transient Protection IAW IEEE C62.41.1, Location Cat. B/C
- Inrush Current: No Greater Than 100% of the Full Load Current
AC Output:
- Power Rating: 60 kVA
- Power Factor Range: 0.5 Lagging to 0.8 Leading
- Overload: 100% Continuous; 110% for 60 min.; 125% for 10 min.; 150% for 2 min.; 200% for 20 sec.
- Crest Factor: 1.414 ± 3%
- Voltage: 115V/200V, 3Ø, 4-Wire, Grounded Neutral
- Voltage Adjust: ±15%
- Voltage Regulation: ±1.0% Under All Conditions of Line, Balanced Loads, and Temperature
- Voltage Transients: IAW MIL-STD-704F
- Frequency Regulation: 400 Hz ± 0.01% Under All Conditions of Line, Loads, and Temperature
- Frequency Transients: None
- Phase Angle Regulation: ±1° for Balanced Loads; ± 2° for Unbalanced Loads
- Harmonic Distortion: 2.0% Maximum
- Protection: Overload, Short Circuit, Overvoltage/Undervoltage, and Safety Disconnect
- Automatic Line Drop Compensation (ALCD): 15%
DC Output:
Model 420
- Full Load Rating: 425 amps continuous
- Overload (10% duty cycle): 600 amps for 1 hour / 1,000 amps for 1 minute
Model 620
- Full Load Rating: 600 amps continuous
- Overload (10% Duty Cycle): 1,000 amps for 1 minute
Model 420/620
- Engine Start Capacity (10% Duty Cycle): Adjustable Up to 1,600 amps for 35 sec. or 2,000 amps for 30 sec.
- Voltage: 28V DC, 2-Wire, Grounded Negative
- Continuous Rated Load and ±10% Input Voltage: ± 0.5%
- No Load to Rated Load with Nominal Input Voltage: ± 0.5%
- Overload with Nominal Input Voltage: See Start Mode Curves
- Voltage Adjust: 28 VDC ± 10%
- Current Limit Adjust: 150A to Full Rated Current
- Protection: Overload, Short Circuit, Overvoltage, and Safety Disconnect
- Automatic Line Drop Compensation (ALDC): 10%
Environmental Specifications
- Acoustical Noise: < 65 dBA Maximum @ 5 ft. (1.5m)
- Temperature Range: -40°C to 55°C (-40°F to 131°F)
- Relative Humidity: 10% to 95%, Non-Condensing
- Ingress of Water: Type 3SX, IP55
| General Information | |
|---|---|
| Part # | UFC-60M-420UDC |
| Manufacturer | Unitron |
| Shipping Information | |
|---|---|
| Freight NMFC | 61700 |
| ECCN | EAR99 |
Customers also viewed
Customers who bought this item also purchased
AIRCRAFT COMPATIBILITY
| Compatible Aircraft* |
|---|
PRODUCT REVIEWS
This item does not have any reviews yet.
QUESTIONS & ANSWERS
There are no questions yet. Be the first to ask.
