12-01144 - Pacific Scientific T5-2002-101-00 Cable Tensiometer
It has been replaced by Pacific Scientific T5-2002-101-00 (Qty 1)
The 12-01144 is a specific part number of the series Pacific Scientific T5-2002-101-00. For more generalized information on this item series or for more options, click here.
Need a Quote?
| Alternate Models | |
|---|---|
| 12-01144 | Alternative Part Number |
| General Information | |
|---|---|
| Part # | 12-01144 |
| Manufacturer | Pacific Scientific |
| Manual 1 | View Manual |
| Shipping Information | |
|---|---|
| Product Weight | 1.7 lbs. |
| Product Dimensions | 7 x 10.5 x 3 in. |
| Schedule B | 9027893500 |
| ECCN | EAR99 |
Customers also viewed
AIRCRAFT COMPATIBILITY
This item is for use on all aircraft.
PRODUCT REVIEWS
QUESTIONS & ANSWERS
The T5‑2002‑101‑00 cable tensiometer should undergo annual recalibration to maintain precision, especially after heavy usage or incidents like overloads or shocks. This ensures consistent tension accuracy and avoids performance degradation due to spring fatigue or mechanical drift.
Because stranded cables can produce slightly varying tension readings across their surface, it’s best to take three to five measurements at slightly different spots along the same cable and use the average value. This technique minimizes error caused by cable inconsistencies and ensures more reliable measurements.
Yes, the T5‑2002‑101‑00 is small and lightweight – ideal for accessing cables in confined or awkward aircraft control pathways. It fits through tight openings and still delivers precise tension readings without needing bulky adjustments.
Absolutely! This tensiometer features a pointer lock mechanism. If the dial isn’t visible, you can engage the brake lever rod to lock the reading in place and then unlock it later for an accurate readout.
Each T5 is factory‑calibrated and supplied with a calibration card that maps dial readings (0 to 100) to tension in pounds. To get the correct load value, you simply match your dial number with the cable size column on the card.
No. The T5 series, including the 2002-101-00, is highly temperature stable. Extreme heat or cold does not affect its accuracy, and it requires no preliminary adjustments .
First, verify cable size using the included gauge, then attach the tensiometer firmly using the proper riser and lever. If visibility is limited, lock the pointer with the brake lever rod. Later, reference the calibration card to convert the dial reading into tension in pounds. Repeat the process at multiple points for an accurate average measurement.
Yes, we carry the complete set of block risers for the T5‑2002‑101‑00 cable tensiometer, including Riser #1 (T555‑2), Riser #2C (T555‑8), and Riser #3 (T555‑6). These risers are also compatible with various other OPTI/Pacific Scientific T5‑2000 series models and are essential for ensuring proper cable contact and accurate tension measurements across different cable sizes. Always consult your model’s calibration chart or manual to confirm riser compatibility for your specific application.
The T5-2002-101-00 supports seven cable diameters: 1/16", 3/32", 1/8", 5/32", 3/16", 7/32", and 1/4". The T5-2001-101-00 covers only the first five sizes up to 3/16". If your aircraft uses 7/32" or 1/4" control cables, the T5-2002-101-00 is the correct model.
The three ranges are: 10–100 lbs for 1/16", 3/32", and 1/8" cables; 15–150 lbs for 5/32" and 3/16" cables; and 25–150 lbs for 7/32" and 1/4" cables. The calibration chart (T594-101) included with each unit maps all dial readings to actual tension in pounds for every cable size and range.
Every unit ships with risers #1, #2C, and #3; an individual factory calibration chart (T594-101); a calibration certificate; and a foam-lined zippered hard carrying case.
Yes. The T5-2002-101-00 is listed under NSN 6635-00-293-0400 and is procurable through government and military supply channels.