What Is a Tronair 17-7505-7000?

The Tronair 17-7505-7000 mobile aircraft air conditioning unit is a high-performance, portable ground cooling system engineered for corporate aviation departments, FBOs, and regional or commuter airlines. Designed to deliver reliable pre-cooling before passenger boarding and efficient temperature control during ramp or maintenance operations, it ensures optimal cabin comfort and equipment protection in all conditions.

This four-ton aircraft air conditioner uses environmentally friendly R-410A refrigerant to provide powerful cooling performance. It operates using either a single-phase 230V, 60Hz power source or its integrated 20HP Honda gas engine-driven motor/generator set, offering flexibility for both hangar and ramp use. Built for durability and ease of operation, the Tronair 17-7505-7000 delivers dependable ground support cooling wherever it’s needed.

Standard Features

General Information
Part #17-7505-7000
ManufacturerTronair
Shipping Information
Shipping Weight1650 lbs.
Shipping Dimensions147 x 71 x 75 in.
Freight NMFC114125
Schedule B8415820115
ECCNEAR99

Customers also viewed

Tronair 17A7505-7000
Gas - 4 Ton - 20 HP Honda Engine - 8.7 kW Heater
Tronair 17-7503B7000
4 Ton - Input Voltage 208V/60Hz/1ph/41.2Amps
Tronair 17A7503J7000
4 Ton - Input Voltage - 460V/60Hz/3ph/13.8Amps - 8.7 kW Heater
Tronair 17-7503G7000
4 Ton - Input Voltage - 230V/60Hz/3ph/25.9Amps
Tronair 17-7503J7000
4-Ton Aircraft Air Conditioner – Input Voltage – 460V / 60 Hz / 3 ph / 13.8 amps

Customers who bought this item also purchased

Tronair 04-6150-0120
Hydraulic Utility Crane, 4,000-lb Capacity
Tronair 11-2820-0000
Portable Ground Power Unit – Tier 4 Final, 28.5V DC Diesel
Tronair 04-6001-1100
B1 Maintenance Platform - 3 to 12 Feet
BAC HT-88
For Bell UH-1, 205, 212, 412 Types - 1 Man Operation

AIRCRAFT COMPATIBILITY

Compatible Aircraft*
*This list is for general reference only and may not be entirely accurate for all aircraft. Please confirm all equipment meets the requirements of your aircraft with the owners/maintenance manuals prior to purchasing or using with your aircraft.

PRODUCT REVIEWS

This item does not have any reviews yet.

QUESTIONS & ANSWERS

Question:
What is the Tronair 17-7505-7000 Aircraft Air Conditioning Unit primarily used for?
Answer:

The Tronair 17-7505-7000 Mobile Air Conditioner is designed to provide ground-based cooling for aircraft cabins during maintenance or when passengers board. It delivers 45,000 BTU/hr of cooling at airflow rates between 1,200 and 2,000 CFM, using R-410A refrigerant for efficient and environmentally responsible operation. Its portability and dual power options make it ideal for use by FBOs, corporate aviation departments, and regional airlines.

Asked October 13, 2025
Question:
What are the power source options for the Tronair 17-7505-7000?
Answer:

This air conditioning unit can operate from either a single-phase 230V AC, 60 Hz power supply or its onboard gasoline-driven motor-generator set. The generator uses a Honda V-Twin 22 HP engine and produces up to 12.5 kW of standby power. This flexibility enables the unit to function seamlessly in both hangars and on remote ramps, eliminating the need for external electrical hookups.

Asked October 13, 2025
Question:
What refrigerant does the Tronair 17-7505-7000 use, and why is it important?
Answer:

The system utilizes R-410A refrigerant, a non-ozone-depleting, environmentally safe refrigerant with high cooling efficiency. R-410A operates at higher pressures than older refrigerants, allowing for more efficient heat exchange and reliable performance in demanding ground service environments. Proper handling is essential – only trained technicians should perform refrigerant charging or leak testing to maintain compliance with EPA guidelines.

Asked October 13, 2025
Question:
What safety precautions should be followed when operating this mobile air conditioner?
Answer:

Operators must ensure the unit is used on a level surface and never operated in enclosed or poorly ventilated areas, as the engine produces carbon monoxide gas. Always verify grounding before operation, avoid overloading the generator, and keep clear of moving parts or hot components. Routine inspection of electrical cords, hoses, and safety labels ensures continued safe operation.

Asked October 13, 2025
Question:
How is the unit’s generator protected against low oil levels?
Answer:

The Honda engine features an automatic low-oil shutdown system that safeguards the generator from damage by shutting the engine off when oil pressure drops below safe levels. The engine cannot be restarted until the oil is replenished, which helps prevent overheating and mechanical wear. Regular oil checks are recommended before each use for optimal reliability.

Asked October 13, 2025
Question:
What are the maintenance requirements for the air conditioning system?
Answer:

Routine maintenance includes cleaning coils and filters, checking for refrigerant leaks, and inspecting all electrical and mechanical connections to ensure optimal performance. The evaporator and condenser coils should be cleaned before each cooling season, and the air filters should be replaced as needed. Fan bearings are permanently lubricated, and the compressor is factory-charged with oil for long-term reliability.

Asked October 13, 2025
Question:
How should the Tronair 17-7505-7000 be stored when not in use?
Answer:

For long-term storage, Tronair recommends cleaning the exterior, changing the engine oil, emptying the fuel system, and disconnecting the battery. The unit should be stored in a clean, dry location away from direct sunlight and corrosive materials. These steps prevent damage to the fuel and electrical systems during extended downtime.

Asked October 13, 2025
Question:
How is the unit’s condensate handled during operation?
Answer:

The Tronair 17-7505-7000 is equipped with a condensate drain system that removes moisture generated during cooling cycles. Operators may direct the drain hose into a collection bucket or attach a garden hose to route condensation away from the work area. It is crucial that the hose end remains below the condensate trap to prevent backflow or potential damage to the equipment.

Asked October 13, 2025
Question:
What type of fuel should be used in the generator’s engine?
Answer:

The engine is designed for unleaded gasoline with an octane rating of 86 or higher (90 or higher in countries using the Research Method). Gasohol with up to 10% ethanol (E10) is acceptable, but higher ethanol blends or alternative fuels are not approved. Stale or contaminated fuel should be avoided to ensure easy starting and clean combustion.

Asked October 13, 2025
Question:
How often should oil and filters be changed?
Answer:

Engine oil should be checked daily and replaced every 100 operating hours, or more frequently in dusty environments. The air cleaner element should be inspected at 25-hour intervals and replaced every 100 hours of operation. Proper lubrication and maintenance significantly extend the lifespan of both the engine and the air conditioning components.

Asked October 13, 2025
Question:
What warranty coverage does Tronair provide for this unit?
Answer:

Tronair warrants the 17-7505-7000 Air Conditioning Unit for one year from the date of shipment against defects in materials or workmanship. Replacement parts are covered for a period of 90 days. Unauthorized modifications or use of non-OEM parts voids the warranty and releases Tronair from liability for damage or injury.

Asked October 13, 2025
Question:
What spare parts are available for this unit?
Answer:

PJi offers a wide range of OEM spare parts for the Tronair 17-7505-7000 air conditioning unit, including replacement wheels (K-2084), batteries (EC-1971), and electrical cables (K-3348).