The new Tronair 90 kVA diesel ground power unit 11-4090-0000 remains ahead of the curve with the latest EPA Tier 4 Final emissions-compliant diesel engine. This GPU is designed to serve as a 90 kVA 400Hz AC power source for parked aircraft.

The award-winning Doosan diesel engine with an industry-leading three-year warranty has electronic controls for more precise control over engine performance. This GPU requires no diesel particulate filter, reducing maintenance interval requirements and improving fuel economy.

SCR regulation and RC circuit ripple filtration ensure a finely tuned unit cable operating with the most sensitive of aircraft. A large Murphy Digital Controller/Display allows the operator to monitor engine parameters and fault codes. An aircraft end cable interlock circuit alerts the operator to a poorly connected cable. End of cable voltage sensing and output voltage drop compensation ensures full power is provided to the aircraft. The large 35-gallon fuel tank allows eight or more hours of run time at the rated load.

Standard Features

Tier 4F Diesel Engine Features & Model

Additional Info

Alternate Models
1190400C128T3Previous Model Number with 28V DC
1190400C1T3Previous Model Number
1190400C28T3Previous Model Number with 28V DC
1190400CT3Previous Model Number
General Information
Part #11-4090-0000
ManufacturerTronair
Warranty
DetailsView Warranty Details
Shipping Information
Shipping Weight4280 lbs.
Shipping Dimensions130 x 92 x 84 in.
Schedule B9032810080
ECCNEAR99

Customers also viewed

Tronair 112860S0100
Single-Output 28V DC Rectifier (GPU) – 60 Hz – 600A Continuous, 2000A Peak Start
Tronair 11-2820-0000
Portable Ground Power Unit – Tier 4 Final, 28.5V DC Diesel
Tronair 11-4290-0000
90 kVA Dual 400 Hz AC & 28V DC Diesel GPU

Customers who bought this item also purchased

Tronair 11-4290-0000
90 kVA Dual 400 Hz AC & 28V DC Diesel GPU
Tronair 10-6401-0010
– 136-Gallon Dump, 68-Gallon Fill
Tronair K-2029
Replacement Wye Coupling Kit with 5’ Hose – Select Tronair Lavatory Service Carts

AIRCRAFT COMPATIBILITY

Compatible Aircraft*
Airbus A220-100 (CS100) , A220-300 (CS300) , A300 , A310 , A318 , A319 , A320 , A321 , A330-200 , A330-300 , A340-200 , A340-300 , A340-500 , A340-600 , A350 , A380
BAe 146-100, -200, -300/Avro RJ70, RJ85, RJ100
Bell UH-1 , UH-1H
Boeing 234 Chinook , 707 , 717 , 727-100 , 727-200 , 737-100 , 737-200 , 737-300 , 737-400 , 737-500 , 737-600 , 737-700 , 737-800 , 737-900 , 737-BBJ , 737-BBJ2 , 747 , 757 , 767 , 777 , DC-8 Series 60 , DC-9 Series 10 , DC-9 Series 20 , DC-9 Series 30 , DC-9 Series 33 , DC-9 Series 40 , DC-9 Series 50 , KC-46 , MD-80
Bombardier Challenger 300 , Challenger 350 , Challenger 600 , Challenger 601 , Challenger 604 , Challenger 650 , Challenger 850 , Challenger 870 , Challenger 890 , CL-215 , CL-215T , CL-415 , CRJ100 , CRJ1000 , CRJ200 , CRJ700 , CRJ705 , CRJ900 , Dash 8-100 , Dash 8-200 , Dash 8-300 , Dash 8-400 , Global 5000 , Global 5500 , Global 6000 , Global 6500 , Global 7000 , Global 7500 , Global 8000 , Global Express , Global Express XRS
Comac ARJ21
Embraer E175-E2 , E190-E2 , E195-E2 , ERJ-170 , ERJ-175 , ERJ-190 , ERJ-195
Fokker 100 , 28 , 50
Gulfstream G350 , G450 , G500 , G550 , G600 , G650 , G650ER , G700 , II , III , IV , IVSP , V , VSP
Lockheed C-130 , L-1011
McDonnell Douglas DC-10 , DC-8 Series 60 , DC-9 Series 10 , DC-9 Series 20 , DC-9 Series 30 , DC-9 Series 33 , DC-9 Series 40 , DC-9 Series 50 , MD-11 , MD-80
Saab 2000
Sikorsky UH-60 Black Hawk, MH-60S Seahawk
*This list is for general reference only and may not be entirely accurate for all aircraft. Please confirm all equipment meets the requirements of your aircraft with the owners/maintenance manuals prior to purchasing or using with your aircraft.

PRODUCT REVIEWS

This item does not have any reviews yet.

QUESTIONS & ANSWERS

Question:
What operational safety features does the Tronair 11-4090-0000 offer?
Answer:

Several integrated safety features help protect users and aircraft during GPU operation. These include an emergency shutoff switch, overvoltage and overcurrent protection circuits, timed engine shutdown, battery shut-off switch, cable interlock protection, and maintenance locks on access doors. The control panel features warning indicators and fault codes, helping operators quickly recognize and address safety concerns. Additionally, engine enclosure insulation ensures sound dampening and improved cold-weather starting.

Asked August 14, 2025
Question:
How is the Tronair 11-4090-0000 maintained, and what are typical maintenance intervals?
Answer:

Routine maintenance is essential for long-term reliability. The fuel and engine oil filters should be changed every 500 hours or six months, and the air cleaner filter must be checked daily and replaced as needed. Regular checks include inspecting fluid levels, hoses, belts, battery terminals, tires, and brakes. Using only ultra-low sulfur diesel and following the manufacturer’s guidelines for preventative care ensures optimal operation and extended engine life, which can reach up to 30,000 hours before a major overhaul.

Asked August 14, 2025
Question:
What are the cold-weather operating capabilities of this ground power unit?
Answer:

Built for reliable performance in cold climates, the Tronair 11-4090-0000 features a 12V, 900CCA AGM battery, automated glow plug control, and a 120V AC block heater for improved cold starts. Its insulated engine enclosure also helps maintain optimal operating temperature and sound dampening, making it suitable for year-round, all-weather airport environments.

Asked August 14, 2025
Question:
How does the unit ensure consistent electrical output for aircraft systems?
Answer:

This GPU uses a cable head voltage sensing and output voltage drop compensation system to guarantee full power delivery to the aircraft even over long cable runs. The SCR regulation and RC circuit ripple filtration provide clean, stable power suitable for sensitive onboard electronics. A large digital controller/display enables real-time monitoring of engine parameters and fault codes, and the interlock circuit alerts users to any improperly connected cables.

Asked August 14, 2025
Question:
What are the recommended practices for storing the Tronair 11-4090-0000 GPU?
Answer:

When not in active service, the unit should be stored in a dry building, with all access doors closed to prevent debris buildup. Fuel tanks should be topped off to prevent moisture ingress, and moisture-absorbing chemicals can be used in high-humidity environments. For long-term storage, draining the coolant and oil, servicing filters, and fully charging batteries are recommended to prevent rust and corrosion. Engine openings and exhaust outlets should be sealed, and the battery must be stored above freezing temperatures.

Asked August 14, 2025
Question:
What signals or alerts indicate abnormal operation or required maintenance?
Answer:

Operators benefit from a Murphy Digital Controller/Display that shows engine status, fault codes, and warning indicators for low fuel, high temperatures, oil pressure, or cable connection issues. Stack lights and corner lights further aid nighttime visibility and fault identification. These features allow personnel to quickly diagnose issues and minimize downtime due to unexpected faults or required preventative care.

Asked August 14, 2025
Question:
What warranty and support are available with the Tronair 11-4090-0000?
Answer:

Tronair provides an industry-leading three-year warranty on the Doosan diesel engine, along with standard product warranties covering manufacturing and material defects for one year after shipment to the original customer. Extended support includes technical assistance, a comprehensive operation/service manual, and a recommended spare parts list for long-term maintenance planning. Only approved OEM replacement parts should be used to retain warranty coverage.

Asked August 14, 2025
Question:
What are the environmental benefits and regulatory compliance features?
Answer:

This GPU is powered by a Tier 4 Final emissions-compliant diesel engine, which meets stringent EPA and European Community emission guidelines without requiring a particulate filter. The design also minimizes fuel consumption and helps reduce the maintenance interval. The CE marking and compliance with relevant machinery and safety standards ensure the unit meets international requirements for environmentally responsible ground support operations.

Asked August 14, 2025
Question:
What is the part number for the replacement fuse holder for this unit?
Answer:

The correct replacement fuse holder for this Tronair ground power unit is part number EC-2882. Using the manufacturer-specified fuse holder ensures proper electrical protection and safe operation of the GPU’s internal systems. Always confirm part compatibility with your equipment’s model and serial number before ordering, and follow the installation procedures outlined in the service manual or by an authorized Tronair service technician.

Asked August 14, 2025